Pampanga State Agricultural University

Office of the Library Services and Museum

Microbial Load Determination Of Selected Pampanga State Agricultural University Water Sources [manuscript] / Ann Klarence C. Duenas.

By: Contributor(s): Material type: TextTextPublication details: Magalang, Pampanga : Pampanag State Agricultural University, April 2015.Description: ix, 48 leaves ; 28 cm. + 1 computer disc (4 3/4 in.)
Contents:
Microbial Load Determination of Selected Pampanga State Agricultural University Water Sources Researcher Ann Klarence C. Duenas School : Pampanga State Agricultural University Degree : Bachelor of Science in Biology April 09, 2015 ee Date completed Adviser : Daniel EB. Gracillia, M.3 Bio This study is entitled "MICROBIAL LOAD DETERMINATION OF SELECTED PAMPANGA STATE AGRICULTURAL UNIVERSITY WATER SOURCES", generally aimed to examine the water safety of the said school for ats bacteriological content. It specifically aimed to identify the _presence of potential pathogenic bacteria such as Salmonella spp., Pseudomonas spp., and E. coli from the water sources, and to find out if the water is safe to use. The method used for the microbiological testing for water samples of PSAU water sources of the Institute of Arts and Sciences was the Most Probable Number and Total Plate Count method. Results of the study revealed that there were coliform becteria on every stations or the selected water sources of Pampanga State Agricultural University. Station 4 exhibited a marge number of coliforms with a 6.4 x 103cfu/ml which considered @6 non-potable or unsafe. Keywords: Salmonella spp.? Psuedomonas spp; E.coli.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Collection Call number Status Barcode
Theses PSAU OLM Dissertation, Theses BS Biology UT D85 2015 (Browse shelf(Opens below)) Not for loan UT12405

Microbial Load Determination of Selected Pampanga State Agricultural University Water Sources Researcher Ann Klarence C. Duenas School : Pampanga State Agricultural University Degree : Bachelor of Science in Biology April 09, 2015 ee Date completed Adviser : Daniel EB. Gracillia, M.3 Bio This study is entitled "MICROBIAL LOAD DETERMINATION OF SELECTED PAMPANGA STATE AGRICULTURAL UNIVERSITY WATER SOURCES", generally aimed to examine the water safety of the said school for ats bacteriological content. It specifically aimed to identify the _presence of potential pathogenic bacteria such as Salmonella spp., Pseudomonas spp., and E. coli from the water sources, and to find out if the water is safe to use. The method used for the microbiological testing for water samples of PSAU water sources of the Institute of Arts and Sciences was the Most Probable Number and Total Plate Count method. Results of the study revealed that there were coliform becteria on every stations or the selected water sources of Pampanga State Agricultural University. Station 4 exhibited a marge number of coliforms with a 6.4 x 103cfu/ml which considered @6 non-potable or unsafe. Keywords: Salmonella spp.? Psuedomonas spp; E.coli.

There are no comments on this title.

to post a comment.