Design, Fabrication And Evaluation Of Automated Dissolved Oxygen And Ph Concentration Monitoring System For Fish Incubator (Record no. 15629)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 02040ntm a2200169 a 4500 |
001 - CONTROL NUMBER | |
control field | 134548 |
003 - CONTROL NUMBER IDENTIFIER | |
control field | 0000000000 |
005 - DATE AND TIME OF LATEST TRANSACTION | |
control field | 20250408094537.0 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 230206n 000 0 eng d |
100 0# - MAIN ENTRY--PERSONAL NAME | |
Personal name | Alonzo, Ferman B. |
245 00 - TITLE STATEMENT | |
Title | Design, Fabrication And Evaluation Of Automated Dissolved Oxygen And Ph Concentration Monitoring System For Fish Incubator |
Medium | [manuscript] / |
Statement of responsibility, etc. | Ferman B. Alonzo. |
260 ## - PUBLICATION, DISTRIBUTION, ETC. | |
Place of publication, distribution, etc. | Magalang, Pampanga : |
Name of publisher, distributor, etc. | Pampanga State Agricultural University, |
Date of publication, distribution, etc. | June 2020. |
300 ## - PHYSICAL DESCRIPTION | |
Extent | xiv, 67 leaves ; |
Dimensions | 28 cm. + 1 computer disc (4 3/4 in.) |
505 0# - FORMATTED CONTENTS NOTE | |
Formatted contents note | Alonzo, Ferman B., Department of Resource Enginecring and Agricultural Mcchanization, College of Resource Enginccring, Automation and Mechanization, Pampanga State Agricultural University, Magalang, Pampanga, June 2020, "Design, Fabrication and Evaluation of Automated Dissolved Oxygen and PH Concentration Monitoring System for Fish Incubator" ADVISER: Engr. Jesus G. Dayrit The study was conducted at a semi-indoor facility in Arayat, Pampanga from November 19, 2019 to March 31, 2020. It is to design, fabncate and evaluate the speed of transfer and the credibility of data of an automated monitomng system for fish incubator. The automated system runs with the logic wntten in the Arduino device and triggers stabilizers when the critical values were attained. The system informs in an hourly basis using SMS sent to the phone. Speed of transfer and the accuracy of its data were obtained to produce evaluation of the system. The code used m the systcm was C language and 1s intcgrated with devices that supports Arduimo. The payback penod of the automated system was 0.64 ycar or 7.68 months. Its breakeven puint was calculated to be 0.17 ycar or 2.05 months. The initial cost of the sysicm and its annual net income were P}7, 437.00 and P12, 452.26 respectively. |
700 1# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Jesus G. Dayrit, |
Relator term | Adviser. |
Withdrawn status | Lost status | Damaged status | Not for loan | Collection | Home library | Current library | Shelving location | Date acquired | Total checkouts | Full call number | Barcode | Date last seen | Price effective from | Koha item type |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Not for loan | BSAg Eng'g | PSAU OLM | PSAU OLM | Dissertation, Theses | 02/06/2023 | UT Al4 2020 | UT12464 | 04/08/2025 | 04/08/2025 | Theses |