Pampanga State Agricultural University

Office of the Library Services and Museum

Internet of things based real-time fire alarm system with sms notification (Record no. 15561)

MARC details
000 -LEADER
fixed length control field 02906ntm a2200169 a 4500
001 - CONTROL NUMBER
control field 134448
003 - CONTROL NUMBER IDENTIFIER
control field 0000000000
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250408094535.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 230201n 000 0 eng d
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Buan, Jayvee B.
245 00 - TITLE STATEMENT
Title Internet of things based real-time fire alarm system with sms notification
Medium [manuscript] /
Statement of responsibility, etc. Jayvee B. Buan.
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Magalang, Pampanga :
Name of publisher, distributor, etc. Pampanag State Agricultural University,
Date of publication, distribution, etc. April 2019.
300 ## - PHYSICAL DESCRIPTION
Extent x, 78 leaves ;
Dimensions 28 cm. + 1 computer disc (4 3/4 in.)
505 0# - FORMATTED CONTENTS NOTE
Formatted contents note Buan, Jayvee B., Castro, Erica M., Garcia, Princess Donna T. Department of Computer Studies and Automation, College of Resource Engineering, Automation and Mechanization, Pampanga State Agricultural University, Magalang, Pampanga, April 2019. "lIOT-BASED REAL-TIME FIRE ALARM SYSTEM WITH SMS NOTIFICATION. Adviser: Jackilyn B. Baccay The study entitled 1}OT-Based Real-Time Fire Alarm System with SMS Notification was design and develop to provide an early warning system for the locale when fire and smoke was detected. The objective of the study was to create a system that will alarm the personne! and fire department immediately when sudden fire incident has occurred; provide the user with a real-time monitoring of temperature, smoke, and fire through mobile application and LCD display; and view the actual scenario inside DCSA office when any of the parameters have triggered. The methodology used by the researchers was the Rapid Application Development, designed to be flexible to changes and to determine the design and flow of the system, different diagrams were also used such as Block Diagram, Network Diagram, System Flowchart, Schematic Diagram, Use Case Diagram, Context Diagram and Data Flow Diagram. The primary data collected in presented questionnaires were interpreted by the used of statistical procedure. Throughout the development of the system, the researchers used WeMos D1 Mini, Arduino Nano and Uno as a microcontroller. Codes were built through Arduino Software IDE using C++ Programming Language. The researchers also used Android Studio using Java Programming Language for the development of the application. The researchers adopted the descriptive method in gathering all the information needed for the development of the study. Through testing the approval of capabilities and functions of the system to the users, the researchers collected a good result in the survey conducted with their respondents. They gathered a grand mean of 3.45 with the Fire Department staffs and DCSA faculty members which means that the respondents agreed that the developed system will be a great of help to prevent fire occurrence immediately. we Ss.
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Jackilyn B. Baccay,
Relator term Adviser.
Holdings
Withdrawn status Lost status Damaged status Not for loan Collection Home library Current library Shelving location Date acquired Total checkouts Full call number Barcode Date last seen Price effective from Koha item type
      Not for loan BS Info. Technology PSAU OLM PSAU OLM Dissertation, Theses 02/01/2023   UT B91 2019 UT12362 04/08/2025 04/08/2025 Theses